Self-Navigated Multi-Contrast And Quantitative Whole Heart 3D Magnetic Resonance Imaging
Lead Research Organisation:
King's College London
Department Name: Imaging & Biomedical Engineering
Abstract
Cardiovascular disease (CVD) remains the leading single cause of death worldwide despite improvements in prevention and advances in diagnosis and treatment. The two major causes for CVD death are sudden coronary atherothrombosis due to plaque rupture and subsequent thrombus formation and heart failure following myocardial infarction (MI) due to adverse myocardial remodeling and subsequent infarct expansion. Detection of coronary atherosclerosis and prediction of adverse myocardial remodeling remain challenging with current imaging techniques. While x-ray coronary angiography is the gold standard for the detection of coronary stenosis it has limited value for the detection and characterization of coronary plaque. Multislice computed tomography (MSCT) is an excellent non-invasive alternative for the detection of coronary stenosis and has some ability to visualize and characterize coronary plaque but its diagnostic use is limited to patients without coronary calcification. Positron electron tomography (PET) has good diagnostic sensitivity for myocardial perfusion and viability assessment and recently also has been shown to have potential for coronary plaque visualization but suffers from low spatial resolution and radiation exposure and is not widely available. Echocardiography is the clinical gold standard for the assessment of left ventricular function and wall motion abnormalities. It is cheap and easy to use but is heavily operator dependent. Due to the above limitations there is a need for the development of an alternative and non-invasive imaging test that allows for comprehensive cardiac assessment without the above restrictions.
Magnetic resonance imaging (MRI) is considered the gold standard for the assessment of cardiac anatomy, left ventricular (LF) function (CINE-MRI), myocardial viability (LGE-MRI) and perfusion (MR-perfusion) due to its excellent soft tissue contrast, high spatial resolution and lack of ionizing radiation according to a Society for Magnetic Resonance (SCMR) expert consensus statement. Recent clinical research studies also have demonstrated its usefulness for quantitative myocardial tissue characterization (T1 and T2 relaxation time mapping) and its ability to differentiate between healthy and diseased tissue. However, a key limitation of the current MRI acquisition scheme is that all imaging sequences (e.g. CINE, LGE, T1 and T2 mapping, coronary MR angiography (MRA), etc.) are acquired sequentially, in different geometric orientations, at different breath-hold positions or using time inefficient navigator gating methods. This imposes several challenges: (1) radiographers need high expertise to perform the complex examination, (2) patients have to perform multiple (>30) breathholds which can be very challenging in sick patients, (3) the duration of the examination is long leading to high operational costs and (4) data fusion is difficult because of the different breathhold positions, scan geometries and non-isotropic spatial resolution. We hypothesize that image based respiratory self-navigation combined with image acceleration techniques will address the above challenges and allow improving the reliability and image quality of free-breathing (no breathholds) three-dimensional (3D) multi-contrast quantitative whole heart cardiac MRI. The proposed approach will enable non-invasive comprehensive cardiac examination with improved patient experience, higher diagnostic yield and improved cost effectiveness thereby improving the treatment and outcome of cardiovascular disease as outlined by the NHS white paper.
Magnetic resonance imaging (MRI) is considered the gold standard for the assessment of cardiac anatomy, left ventricular (LF) function (CINE-MRI), myocardial viability (LGE-MRI) and perfusion (MR-perfusion) due to its excellent soft tissue contrast, high spatial resolution and lack of ionizing radiation according to a Society for Magnetic Resonance (SCMR) expert consensus statement. Recent clinical research studies also have demonstrated its usefulness for quantitative myocardial tissue characterization (T1 and T2 relaxation time mapping) and its ability to differentiate between healthy and diseased tissue. However, a key limitation of the current MRI acquisition scheme is that all imaging sequences (e.g. CINE, LGE, T1 and T2 mapping, coronary MR angiography (MRA), etc.) are acquired sequentially, in different geometric orientations, at different breath-hold positions or using time inefficient navigator gating methods. This imposes several challenges: (1) radiographers need high expertise to perform the complex examination, (2) patients have to perform multiple (>30) breathholds which can be very challenging in sick patients, (3) the duration of the examination is long leading to high operational costs and (4) data fusion is difficult because of the different breathhold positions, scan geometries and non-isotropic spatial resolution. We hypothesize that image based respiratory self-navigation combined with image acceleration techniques will address the above challenges and allow improving the reliability and image quality of free-breathing (no breathholds) three-dimensional (3D) multi-contrast quantitative whole heart cardiac MRI. The proposed approach will enable non-invasive comprehensive cardiac examination with improved patient experience, higher diagnostic yield and improved cost effectiveness thereby improving the treatment and outcome of cardiovascular disease as outlined by the NHS white paper.
Planned Impact
Our goal is to maximise the impact of our work through dissemination of our ideas and results to the academic and clinical communities and potential industrial partners. The scientific methodology results from this research will be output as research publications in high-impact journals in the field of medical imaging and cardiology. Target journals will include Magnetic Resonance in Medicine, Circulation and Radiology. Dissemination will also take place through presentations at the major international academic conferences, especially the International Society for Magnetic Resonance in Medicine (ISMRM) and the Society for Cardiovascular Magnetic Resonance (SCMR).
A large amount of phantom and in-vivo cardiac MR data will be generated during the lifetime of this grant. We will protect any resulting intellectual property in consultation with KCL Enterprises. After the studies are published in scientific journals, and after they are patented if patenting is a viable option, this data will be made publicly available for research use. After completion of the project we also plan to share the developed software with other MR researchers and clinicians interested in our methods in order to validate the developed imaging methods at other medical centres and/or to further improve the methodology. Moreover, we will work closely with the manufactures to develop works in progress packages that can be easily shared with other universities or medical centres and that will also allow rapid translation of the developed methods into commercial products of the vendors. This will facilitate wider spread clinical use of this research and enhance the clinical impact of this research. The Division has a Master Research Agreement both with Philips and Siemens providing access to acquisition and reconstruction source code. Philips is currently funding, through our new EPSRC Centre for Doctoral Training (CDT) in Medical Imaging at KCL/Imperial College, one PhD student working on motion corrected 3D T1 mapping under the supervision of the PI, which is relevant to this project. Throughout the project we will post blogs about our latest results on the Division's blog (https://kingsimaging.wordpress.com/) to reach a larger community and to make our research results more accessible to a larger community. In addition, we will participate in the "Pint of Science" 3-day annual festival and present our research results in pubs around London to engage with local communities. We also plan to present to the Public and Patient Involvement Cardiovascular group at Guy's and St Thomas' Hospital to provide updates and receive patient feedback (http://www.guysandstthomasbrc.nihr.ac.uk/PatientsPublic/Getinvolved/Haveyoursay/Cardiovascular.aspx).
A large amount of phantom and in-vivo cardiac MR data will be generated during the lifetime of this grant. We will protect any resulting intellectual property in consultation with KCL Enterprises. After the studies are published in scientific journals, and after they are patented if patenting is a viable option, this data will be made publicly available for research use. After completion of the project we also plan to share the developed software with other MR researchers and clinicians interested in our methods in order to validate the developed imaging methods at other medical centres and/or to further improve the methodology. Moreover, we will work closely with the manufactures to develop works in progress packages that can be easily shared with other universities or medical centres and that will also allow rapid translation of the developed methods into commercial products of the vendors. This will facilitate wider spread clinical use of this research and enhance the clinical impact of this research. The Division has a Master Research Agreement both with Philips and Siemens providing access to acquisition and reconstruction source code. Philips is currently funding, through our new EPSRC Centre for Doctoral Training (CDT) in Medical Imaging at KCL/Imperial College, one PhD student working on motion corrected 3D T1 mapping under the supervision of the PI, which is relevant to this project. Throughout the project we will post blogs about our latest results on the Division's blog (https://kingsimaging.wordpress.com/) to reach a larger community and to make our research results more accessible to a larger community. In addition, we will participate in the "Pint of Science" 3-day annual festival and present our research results in pubs around London to engage with local communities. We also plan to present to the Public and Patient Involvement Cardiovascular group at Guy's and St Thomas' Hospital to provide updates and receive patient feedback (http://www.guysandstthomasbrc.nihr.ac.uk/PatientsPublic/Getinvolved/Haveyoursay/Cardiovascular.aspx).
Publications
Nazir MS
(2022)
High-resolution non-contrast free-breathing coronary cardiovascular magnetic resonance angiography for detection of coronary artery disease: validation against invasive coronary angiography.
in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
Fotaki A
(2022)
Efficient non-contrast enhanced 3D Cartesian cardiovascular magnetic resonance angiography of the thoracic aorta in 3 min.
in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
Milotta G
(2021)
3D whole-heart grey-blood late gadolinium enhancement cardiovascular magnetic resonance imaging.
in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
Qi H
(2020)
Respiratory motion-compensated high-resolution 3D whole-heart T1? mapping.
in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
Henningsson M
(2017)
Diagnostic performance of image navigated coronary CMR angiography in patients with coronary artery disease.
in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
Hajhosseiny R
(2021)
Clinical comparison of sub-mm high-resolution non-contrast coronary CMR angiography against coronary CT angiography in patients with low-intermediate risk of coronary artery disease: a single center trial.
in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
Ginami G
(2017)
3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiography.
in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
Jaubert O
(2021)
T1, T2, and Fat Fraction Cardiac MR Fingerprinting: Preliminary Clinical Evaluation.
in Journal of magnetic resonance imaging : JMRI
Nordio G
(2017)
3D myocardial T1 mapping using saturation recovery.
in Journal of magnetic resonance imaging : JMRI
Rashid I
(2023)
Magnetization Transfer BOOST Noncontrast Angiography Improves Pulmonary Vein Imaging in Adults With Congenital Heart Disease.
in Journal of magnetic resonance imaging : JMRI
Description | A new set of imaging tools for the non-invasive and radiation-free assessment of the anatomy of the coronary arteries and myocardium have been developed. These include the development of advanced respiratory motion correction methods which include beat-to-beat translational motion correction using image navigators (iNAV) and bin-to-bin non-rigid motion correction using the imaging data itself thereby allowing for shorter and predictable scan time resulting in improved image quality. In addition, novel imaging sequences were developed which allow the simultaneous visualisation of the coronary vessels, coronary thrombus, high intensity plaque and myocardial scar (BOOST sequence). These techniques now have been combined with advanced undersampling reconstruction techniques (ORCCA and PROST), which allow respiratory motion resolved reconstruction and highly undersampled reconstruction (3-4 fold) of non-rigid motion corrected whole heart coronary MR angiography (CMRA) datasets. To enable multi centric clinical validation we have developed works in progress packages (WIPs) together with Siemens Healthineers for our CMRA and BOOST sequence. The CMRA WIP also includes the option of performing free-breathing high-resolution motion corrected 3D myocardial viability imaging with and without black blood option, which is important for detection of small infarctions or arrhythmic substrate. The multi-contrast BOOST sequence has also been extended to allow joint T1/T2 mapping (Milotta G et al. MRM 2020) and was combined with the latest motion correction and image reconstruction developments to further increase image resolution and shorten scan time. We also have developed a motion corrected free running 3D whole heart T1 and joint T1/T2 mapping technique for simultaneous assessment of fibrosis and edema and which is based on a 3D radial trajectory and a low rank patched based reconstruction. All sequences are currently tested in patients with cardiovascular disease. Specifically, we have scanned 50 patients referred from the CTCA list with our high resolution CMRA protocol (0.9mm3) with the CMRA images approaching CT image quality but without the need for radiation or nephrotoxic contrast agents. The highlight of this clinical study is that all CMRA were completed successfully and that 97% of the proximal and 94% of the middle coronary segments were of diagnostic image quality (vs 99% and 98% for CTCA). Specificity and negative predicative value for identification of coronary artery disease were 93-98% and 95-100% for LM, LAD, RCA and LCx. We also have scanned 25 patients with congenital heart disease with our BOOST sequence which outperformed the clinical protocol in terms of image quality and diagnostic yield. |
Exploitation Route | Taken in combination, these developments will enable a better stratification of patients and therefore more personalized care of high-risk patients with more expensive technologies, as well as early diagnosis and better primary/secondary prevention. Impacts 1. Significant progress towards clinically applicable and robust methods for anatomical and functional assessment of CAD. 2. Significant progress towards clinically applicable and robust methods for simultaneous assessment of coronary lumen integrity and high intensity coronary plaque. 3. Significant progress towards clinically applicable and robust methods for simultaneous assessment of coronary lumen and myocardial tissue integrity. 4. Significant progress towards clinically applicable and robust methods for high resolution myocardial viability imaging both with black blood and grey blood 3D LGE. 5. Significant progress towards clinically applicable and robust methods for high resolution myocardial T1 and T2 mapping. 6. Significant progress towards clinically applicable and robust methods for high resolution and accelerated coronary angiography using advanced motion correction and reconstruction methods. |
Sectors | Digital/Communication/Information Technologies (including Software) Healthcare Pharmaceuticals and Medical Biotechnology |
Description | This grant has led to the development of a new software product that we developed in close collaboration with Siemens Healthineers. We recently launched new product 3D WholeHeart Pro at the CMR2024 international conference in London, UK. The meeting attracted 2800 expert in the field of cardiovascular imaging and the product release attracted 200 attendees with the room being fully booked out. I attached the link to the talk where I describe the research that led to this product release. https://www.magnetomworld.siemens-healthineers.com/clinical-corner/case-studies/3d-whole-heart-page In addition, this research has led to development of a prototype MR sequence jointly developed with Siemens Healthineers that allows to simultaneously acquire whole heart 3D bright and black blood anatomical images as well as 3D parametric maps for tissue characterisation (fibrosis and inflammation). |
First Year Of Impact | 2024 |
Sector | Healthcare,Pharmaceuticals and Medical Biotechnology |
Description | Contrast-free Deep Myocardial Tissue Characterization with Cardiac MR Fingerprinting |
Amount | £932,527 (GBP) |
Funding ID | EP/V044087/1 |
Organisation | Engineering and Physical Sciences Research Council (EPSRC) |
Sector | Public |
Country | United Kingdom |
Start | 09/2021 |
End | 09/2024 |
Description | Detection of High-Risk Plaque with tropoelastin-specific and multicontrast coronary MRI |
Amount | £1,258,715 (GBP) |
Funding ID | RG/20/1/34802 |
Organisation | British Heart Foundation (BHF) |
Sector | Charity/Non Profit |
Country | United Kingdom |
Start | 01/2021 |
End | 12/2025 |
Description | Gadolinium-free multi-contrast 3D whole-heart MRI for improved management of patients with congenital heart disease |
Amount | £294,199 (GBP) |
Organisation | British Heart Foundation (BHF) |
Sector | Charity/Non Profit |
Country | United Kingdom |
Start |
Description | Improved 3D Whole-heart MR Imaging for the Assessment of Cardiac Anatomy in Paediatric Congenital Heart Disease |
Amount | £57,869 (GBP) |
Organisation | Engineering and Physical Sciences Research Council (EPSRC) |
Sector | Public |
Country | United Kingdom |
Start |
Description | Multi-parametric tissue characterisation of myocardial inflammation in autoimmune rheumatic diseases using cardiovascular magnetic resonance imaging |
Amount | £255,962 (GBP) |
Funding ID | FS/20/13/34857 |
Organisation | British Heart Foundation (BHF) |
Sector | Charity/Non Profit |
Country | United Kingdom |
Start |
Description | Multidimensional and Multiparametric Quantitative Cardiac MRI from Continuous Free-Breathing Acquisition |
Amount | £565,581 (GBP) |
Funding ID | EP/P032311/1 |
Organisation | Engineering and Physical Sciences Research Council (EPSRC) |
Sector | Public |
Country | United Kingdom |
Start | 08/2017 |
End | 08/2021 |
Description | Simultaneous Non-Contrast Free Breathing 3D High Resolution Magnetic Resonance Coronary Artery Angiography and High-Risk Plaque Imaging |
Amount | £178,187 (GBP) |
Funding ID | FS/CRTF/20/24011 |
Organisation | British Heart Foundation (BHF) |
Sector | Charity/Non Profit |
Country | United Kingdom |
Start | 09/2020 |
End | 09/2022 |
Description | Charité Berlin |
Organisation | Charité Campus Virchow - Hospital |
Country | Germany |
Sector | Academic/University |
PI Contribution | We have provided the partner with a cardiac PET-MR sequence and two multi-contrast whole heart MRI sequences for validation in patients with coronary artery disease. |
Collaborator Contribution | There are no contributions yet as we are waiting for the signing of the material transfer agreement. |
Impact | None so far. |
Start Year | 2018 |
Description | Technical University Munich |
Organisation | Technical University of Munich |
Department | Department of Nuclear Medicine |
Country | Germany |
Sector | Academic/University |
PI Contribution | We have developed a novel motion corrected cardiac PET-MR sequence that allows to simultaneously acquire a coronary MR angiogram and the PET list mode data whereby motion correction is performed in 2 steps; First translational motion correction is performed using the MR image navigator and secondly both the MR and PET data a assigned to 4-5 respiratory bins. From the binned MR data, non-rigid motion fields are estimated that are then used to correct both the MR and PET data on a bon-to-bin basis. We provided our collaborators in Munich with this novel sequence, wich has been published in MRM and they used this PET-MRI imaging sequence in patients with coronary occlusion. |
Collaborator Contribution | Our partners recruited 15 patients with coronary occlusion, as confirmed by x-ray angiography, and scanned those patients with our novel PET-MR sequence. They performed the PET image analysis before and after motion correction. This study demonstrated that MR based motion correction can improve PET myocardial viability images. In some patients a mural infarct was re-classified as non-transmural after motion correction. The study has been submitted to the European Journal of Nuclear Medicine. |
Impact | The results of this collaboration has been submitted to the European Journal of Nuclear Medicine. |
Start Year | 2017 |
Description | University of Aarhus Denmark |
Organisation | Aarhus University |
Country | Denmark |
Sector | Academic/University |
PI Contribution | The MR coronary angiography sequence developed with this award will be investigated in a multi centre trial together with Aarhus University who is the core lab for CT coronary angiography while King´s College London is the core lab for MR coronary angiography. We are planning to recruit 250 patients with suspected coronary artery disease and compare against the clinical gold standard CTA and X-ray coronary angiography. |
Collaborator Contribution | The partner will jointly recruit around 100 patients with suspected coronary artery disease and perform coronary MR angiography with the prototype sequence my group developed at King´s. Aarhus will be in charge of the CT analysis in this multi centre trial while my team at King´s will be responsible for the MR analysis. |
Impact | This collaboration is ongoing and has led so far to one joint publication. Automated detection of cardiac rest period for trigger delay calculation for image-based navigator coronary magnetic resonance angiography. Wood G, Pedersen AU, Kunze KP, Neji R, Hajhosseiny R, Wetzl J, Yoon SS, Schmidt M, Nørgaard BL, Prieto C, Botnar RM, Kim WY. J Cardiovasc Magn Reson. 2023 Oct 2;25(1):52. doi: 10.1186/s12968-023-00962-9. |
Start Year | 2021 |
Description | University of Bordeaux |
Organisation | University of Bordeaux |
Country | France |
Sector | Academic/University |
PI Contribution | We have provided our collaborators from the electrophysiology department with novel MRI pulse sequences (acquisition and reconstruction software) that we developed, which their are planning to use our MR sequences in large animal models and patients to perform myocardial tissue characterisation to guide interventional procedures. The collaborators are going to obtain our latest pre-product MR software to validate its usefulness for coronary angiography and late gadolinium enhancement MRI of the myocardium and atrial walls. |
Collaborator Contribution | So far our partner have not produced any published results. |
Impact | None so far. |
Start Year | 2018 |
Description | University of Nantes |
Organisation | University of Nantes |
Country | France |
Sector | Academic/University |
PI Contribution | We are providing our partner with novel MRI sequences that we have to developed in order to test those in patients with cardiovascular disease. The aim is to validate if our MRI sequences will allow detecting coronary intraplaque haemorrhage, which is considered a novel biomarker for future coronary events. |
Collaborator Contribution | No output yet, as we are waiting to sign a material transfer agreement. |
Impact | No outputs yet. |
Start Year | 2018 |
Title | A method and apparatus for generating a T1-T2 map |
Description | A method for generating a T1 and/or T2 map for a three-dimensional image volume comprises acquiring first, second, and third 3D images of the image volume using different MR acquisition parameters. Signal evolutions of the voxels through the first to third images are obtained by comparing voxel intensity levels of corresponding voxel locations in the three images. A simulation dictionary representing the signal evolutions for a number of different tissue parameter combinations is obtained by simulations e.g. using Bloch equations or extended phase graph (EPG) methods. The T1 and/or T2 map is generated by comparing the determined signal evolutions to entries in the dictionary and by finding, for each of the determined signal evolutions, the entry in the dictionary that best matches the determined signal evolution. The method may be used in cardiac imaging. The first image may use an inversion recovery preparation pulse, the second image may use no preparation pulse, and the third image may use a T2 preparation pulse. |
IP Reference | GB2581168 |
Protection | Patent application published |
Year Protection Granted | 2020 |
Licensed | No |
Impact | This methods enables high-resolution tissue characterization and has led to the creation of a Siemens co-funded PhD studentship. |
Title | METHOD AND APPARATUS FOR GENERATING A T1/T2 MAP |
Description | A method and apparatus for generating a T1 or T2 map for a three-dimensional (3D) image volume of a subject. The method includes acquiring first, second, and third 3D images of the image volume of the subject. Signal evolutions of voxels through the first to third 3D images by comparing voxel intensity levels of corresponding voxel locations in the first, second, and third 3D images. A simulation dictionary representing the signal evolutions for a number of different tissue parameter combinations is obtained. The T1 or T2 map is generated by comparing the determined signal evolutions to entries in the dictionary and by finding, for each of the determined signal evolutions, the entry in the dictionary that best matches the determined signal evolution. |
IP Reference | US2020249299 |
Protection | Patent application published |
Year Protection Granted | 2020 |
Licensed | No |
Impact | This development had led to a joint patent application between King's College London and Siemens Healthineers. It also has led to the funding of a PhD project to extend the developed method to also quantify T2* and thus tissue iron concentration. Moreover, we are working towards a works in progress package together with Siemens Healthineers which is a prototype sequence required for commercialisation. |
Title | METHOD AND APPARATUS FOR RECONSTRUCTING MAGNETIC RESONANCE IMAGE DATA |
Description | In a method for reconstructing magnetic resonance (MR) image data from k-space data, k-space data of an image region of a subject are provided to a computer that is also provided with multiple navigator signals for the image region of the subject. The computer sorts the k-space data into multiple bins, the multiple bins representing different motion states of the subject. For each of the multiple bins, the computer executes a compressed sensing procedure to reconstruct the MR image data from the k-space data in the respective bin. Execution of the compressed sensing procedure includes solving an optimization problem comprising a data consistency component and a transform sparsity component. Motion information is incorporated by the computer into at least one of the data consistency component and the transform sparsity component of the optimization problem. |
IP Reference | US2019317172 |
Protection | Patent application published |
Year Protection Granted | 2019 |
Licensed | No |
Impact | No licensing has occurred so far. |
Title | METHOD OF PERFORMING MAGNETIC RESONANCE IMAGING AND A MAGNETIC RESONANCE APPARATUS |
Description | In a method of performing magnetic resonance (MR) imaging, an MR apparatus, and a computer-readable medium during a first cardiac cycle of a subject, a first imaging sequence is generated for application to a subject. The first imaging sequence has a preparatory pulse and an inversion recovery pulse following the preparatory pulse. First signals emitted from the subject in response to the first imaging sequence are detected, and first image data are generated based on the first signals. During a second cardiac cycle following the first cardiac cycle, a second imaging sequence is generated for application to the subject. The second imaging sequence has a preparatory pulse. Second signals emitted from the subject in response to the second imaging sequence are detected, and second image data are generated based on the second signals. |
IP Reference | US2019064299 |
Protection | Patent application published |
Year Protection Granted | 2019 |
Licensed | No |
Impact | No licensing has occurred so far. |
Title | METHOD OF RECONSTRUCTING MAGNETIC RESONANCE IMAGE DATA |
Description | A method of reconstructing magnetic resonance (MR) image data from k-space data. The method includes obtaining k-space data of an image region of a subject; and reconstructing, using a sparse image coding procedure, the MR image data from the k-space data by performing an iterative optimization method. The optimization method includes a data consistency iteration step and a denoising iteration step applied to MR image data generated by the data consistency iteration step. The denoising iteration step incorporates a sparsifying operation to provide a sparse representation of the MR image data for the imaged region as an input to the data consistency iteration step. |
IP Reference | US2019346522 |
Protection | Patent application published |
Year Protection Granted | 2019 |
Licensed | No |
Impact | No licensing has occurred so far. |
Title | METHOD OF RECONSTRUCTING MAGNETIC RESONANCE IMAGE DATA |
Description | A plurality of sets of k-space data each of the same image region of a subject but having different contrasts are obtained. A sparse image coding procedure is performed to reconstruct a plurality of MR images each corresponding to one of the sets of k-space data. This involves solving an optimization problem comprising a data consistency iteration step used to generate the reconstructed MR images; and a denoising iteration step applied to the reconstructed MR images generated during the data consistency iteration step. The denoising iteration step includes performing a 2D/3D block matching operation to identify similar patches across the reconstructed MR images, and using the similar patches across the reconstructed MR images in a sparsifying operation to provide sparse representations of the reconstructed MR images. The sparse representations are used as an input to the data consistency iteration step. |
IP Reference | US2020241096 |
Protection | Patent application published |
Year Protection Granted | 2020 |
Licensed | No |
Impact | This invention has enabled the development of many new multi-contrast cardiac MR sequences that were not feasible before by significantly speeding up image acquisition time by exploiting data redundancies in multiple dimensions. |
Title | Method and apparatus for correcting motion in K-Space data acquired in a magnetic resonance imaging procedure |
Description | A method of correcting for motion in k-space data acquired during a magnetic resonance imaging (MRI) procedure comprising: acquiring a plurality of out-of-phase 2D image navigators 101 each representing, in the image domain, a 2D image of an image region of a subject; acquiring k-space data 102 representing, in the frequency domain, a plurality of 3D MRI images of the image region of the subject; and correcting for motion within the acquired k-space data 103 using motion information for the subject obtained from the plurality of out-of-phase 2D image navigators so as to generate motion corrected k-space 104; and an associated apparatus including a gradient system to apply a magnetic field gradient, an excitation system, a computing system in communication with the excitation system, and the gradient system for controlling these components. The k-space data may be sorted into bins (fig.2B, 213a,213b,213c) representing different motion states of the subject and a plurality of in-phase 2D image navigators may be acquired. |
IP Reference | GB2582338 |
Protection | Patent application published |
Year Protection Granted | 2020 |
Licensed | No |
Impact | This invention has enabled the detection of respiratory motion during cardiac MRI in multi-contrast images by providing fat images that are insensitive to contrast change in comparison to the typical water images. |
Title | 3D Whole Heart Plus |
Description | We have developed a product MRI sequence jointly with Siemens Healthineers to non-invasively image the coronary arteries. This development was funded by several EPSRC grants and BHF grants. We are currently waiting for FDA approval. The product sequence has been launched during the CMR2024 meeting in London, UK. |
Type | Diagnostic Tool - Imaging |
Current Stage Of Development | Market authorisation |
Year Development Stage Completed | 2024 |
Development Status | Under active development/distribution |
Impact | This new MR imaging sequence has been tested n 3500 patients at more than 20 medical centers on 4 continents. |
URL | https://www.magnetomworld.siemens-healthineers.com/clinical-corner/case-studies/3d-whole-heart-page |
Title | Development of image navigator for respiratory motion correction in whole heart MRI |
Description | We developed a new motion correction technique, which employs low resolution 2D images of the heart, prior to data acquisition to correct for respiratory motion on a heartbeat to heartbeat basis. The image navigator has been implemented both in the Philips and Siemens MR acquisition and reconstruction software and provides the clinician both with non-corrected and motion corrected images at the scanner console. |
Type Of Technology | Software |
Year Produced | 2018 |
Impact | The image navigator allows for 100% scan efficiency without any data rejection and makes whole heart MRI more reliable and scan time predictable compared to gating approaches, which can lead to prolonged scan times. The image navigator has been combined with several whole heart sequences (coronary MRA, late gadolinium enhancement, magnetisation transfer ratio, T1 and T2 mapping). We have now started several collaboration with academic institutions that are interested in evaluating this technology in patients with heart disease. |
Title | Pre-product BOOST MRI sequence for simultaneous MR coronary angiography and plaque imaging |
Description | We developed a pre-product with Siemens Helathineers which allows the simultaneous acquisition of a bright and black blood dataset that can be used for MR coronary angiography and plaque imaging. |
Type Of Technology | New/Improved Technique/Technology |
Year Produced | 2021 |
Impact | The BOOST sequence is currently validated against X-ray angiography and optical coherence tomography (OCT) for vulnerable plaque detection at Hammersmith Hospital. Correlation with X-ray and OCT are excellent suggesting that BOOST may be a non-invasive alternative. |
Title | Pre-product MR sequence for coronary angiography and myocardial scar imaging |
Description | We developed a novel MRI sequence both for coronary angiography and myocardial scar imaging that is currently tested worldwide by Siemens customers and is planned to become a product in 2022. |
Type Of Technology | New/Improved Technique/Technology |
Year Produced | 2020 |
Impact | This pre-product MR sequence has been requested by several leading physician scientists for clinical testing and is currently being evaluated at more than 5 centres worldwide (e.g. Charité Berlin, U Bordeaux, PUC in Beijing, U Bordeaux, U Nantes). |
Description | Pint of Science activity in London |
Form Of Engagement Activity | A talk or presentation |
Part Of Official Scheme? | No |
Geographic Reach | Regional |
Primary Audience | Public/other audiences |
Results and Impact | We presented our work at the Pint of Science in London where we had several talks about the use of medical imaging for the diagnosis and treatment of heart disease. |
Year(s) Of Engagement Activity | 2016 |
Description | Royal Society Summer Science Festival |
Form Of Engagement Activity | Participation in an activity, workshop or similar |
Part Of Official Scheme? | No |
Geographic Reach | National |
Primary Audience | Public/other audiences |
Results and Impact | We took part of the Royal Society Summer Science Festival and had a stand demonstrating our research in cardiovascular imaging called "Heart in your Hands". Several hundred people attended our stand every day and all attendees were very engaged with our PhD students and postdocs who explained our research in lay words. |