Quantitative, high resolution two-and-three dimensional dopant mapping in the Scanning Electron Microscope by Secondary Electron Spectro-Micro

Lead Research Organisation: University of Sheffield
Department Name: Materials Science and Engineering

Abstract

Mobile phones and modern electronic devices in general are becoming increasingly smaller, faster and more powerful. This is possible because electronic circuits required for their operation become smaller and smaller allowing the devices to shrink or to add more circuits in the same volume. These circuits are based on the principle that the conductivity in certain well specified areas changes when a voltage is applied. This is achieved by putting a few atoms with fewer or more electrons, called dopant atoms, into a semiconductor material such as silicon. It is crucial that exactly the correct number of atoms are put into exactly the right place. This is challenging in itself but in addition we have to make sure that we can confirm that we have achieved the right number of dopant atoms in the right place, because otherwise the device will not work to its specification. This is called dopant mapping because it links the number of dopant atoms to spatial coordinates in one (1D), two (2D) or three(3D) dimensions. For future devices we need to know how the number of dopants changes within three nanometers in 3D. The main aim of the work proposed here is to provide a solution to the above challenge. Because it is such a difficult problem to tackle many techniques have been developed so far but all have short comings. One such technique is to use a scanning electron microscope (SEM), where electrons of certain energy impinge on a surface causing other electrons, called secondary electrons (SE)s, to leave that surface. The number of SEs depends on the number of dopant atoms in the irradiated region but in a complex way and accurate quantification is therefore difficult. Also this approach does not have the potential to give us the information we need from regions as small as 3nm in diameter because, even when our impinging electron beam is that small, SEs in silicon can come from atoms12 times further below the surface. To solve this problem we propose to exploit another property of the SEs and this is their energy. SEs have a range of energies (energy spectrum) depending on how deep below the surface they were generated. We anticipate that we will be able to locate dopant atoms with a few nanometer resolutions by using high energy SEs only. We hope to obtain an accurate quantification by measuring the shift of the energy spectra of differently doped regions. To extend the 2D technique to 3D we need to remove thin layers of material in a controlled way and apply the 2D technique for each layer. Focused ion beam (FIB) instruments are made for this purpose and operate by firing Ga+ ions of a certain energy (normally 30kV) at the target surface, which leads to the removal of target surface atoms. A side effect of this technique is the incorporation of Ga in the surface. We have found that this effect is so pronounced at 30kV that a quantification of dopants is not possible. Therefore we propose to add a special low energy module to our existing FIB that allows us to reduce the Ga ion energy by up to 120 times, thus reducing the incorporation of Ga and other damage in the target surface. The proposed work addresses all the issues which currently hamper accurate, high resolution (3D) dopant mapping in the SEM. It therefore has the potential to bring us all one step closer to smaller, better and more powerful semiconductor devices in the future.

Publications

10 25 50
publication icon
Chee K (2008) High resolution dopant profiling in the SEM, image widths and surface band-bending in Journal of Physics: Conference Series

publication icon
Dapor M (2009) The effect of oxide overlayers on secondary electron dopant mapping. in Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada

publication icon
Jepson M (2009) Quantitative dopant contrast in the helium ion microscope in EPL (Europhysics Letters)

publication icon
Jepson M (2010) The effect of oxidation and carbon contamination on SEM dopant contrast in Journal of Physics: Conference Series

publication icon
Jepson M (2010) Progress towards site-specific dopant profiling in the scanning electron microscope in Journal of Physics: Conference Series

publication icon
Jepson M (2009) Dopant contrast in the helium ion microscope in EPL (Europhysics Letters)

publication icon
Jepson M (2011) Resolution limits of secondary electron dopant contrast in helium ion and scanning electron microscopy. in Microscopy and microanalysis : the official journal of Microscopy Society of America, Microbeam Analysis Society, Microscopical Society of Canada

publication icon
Rodenburg C (2010) Dopant contrast in the Helium Ion Microscope: contrast mechanism in Journal of Physics: Conference Series

publication icon
Rodenburg C (2011) Surface morphology of silica nanowires at the nanometer scale in Journal of Non-Crystalline Solids

publication icon
Rodenburg C (2010) Advantages of Energy Selective Secondary Electron Detection in SEM in Microscopy and Microanalysis

publication icon
Rodenburg C (2010) Energy filtered scanning electron microscopy: Applications to dopant contrast in Journal of Physics: Conference Series

 
Description Modern electronic devices are becoming increasingly smaller, faster and more powerful. This is possible because electronic circuits required for their operation become smaller and smaller allowing the devices to shrink or to add more circuits in the same volume. These circuits are based on the principle that the conductivity in certain well specified areas changes when a voltage is applied. This is achieved by putting a few atoms with fewer or more electrons, called dopant atoms, into a semiconductor material such as silicon. It is crucial that exactly the correct number of atoms are put into exactly the right place. Dopant mapping because it links the number of dopant atoms to spatial coordinates

We have experimentally shown that using only part of the SEs energy spectrum can result in accurately locating junctions, see dopant distributions, even when covered by contamination or damaged layers, and in some cases enabled us to get better resolution.

We have also tested dopant contrast formation in a new type of microscope, the Helium Ion Microscope (HeIM), which is similar to SEMs but uses a very finely focused beam (~0.6nm) of helium ions to generate SEs for image formation. We found that this small probe alone does not lead to a greatly improved resolution because it is surface effects that distort the dopant profile, as confirmed by computer modelling (also carried out as part of this project) of dopant contrast formation. We have shown how a plasma can be used to alter the dopant contrast mechanism and improve resolution.

To make the area from which a dopant profile is required accessible was another challenge we worked on successfully during this project. Focused ion beam (FIB) instruments are made for this purpose and operate by firing Ga+ ions of a certain energy (normally 30kV) at the target surface, which leads to the removal of target surface atoms. A side effect of this technique is the incorporation of Ga in the surface. We have found that this effect is so pronounced at 30kV that a quantification of dopants is not possible. Therefore we used 30kV Ga ions followed by Ar ions, as well as 5keV and 10keV Ga ions followed by plasma cleaning. When the latter is combined with selecting low energy SEs only for image formation very good results were obtained.

The expertise developed in Helium Ion Microscopy in relation to dopant mapping on inorganic semiconductors has led to further Helium Ion Microscopy work on different materials systems including coatings to lower friction, polymers for tissue engineering, organic solar cell active layers and silica nanowires. In each case using the HeIM and quantitative image analysis has lead to new insights on the nano-scale chemistry and/ or structure of these materials, not accessible by other methods but critical to further develop these types of materials for different applications.
Exploitation Route has been taken forward, research has been applied to organic solar cell active layers, is planned to be further developed for other organic materials (first feasibility tests carried out for potential industrial end user in the chemical industry),
energy filtering system is used for characterization in wider organic electronics through Royal Society International Exchanges program with Trinity College Dublin, Energy Filtering system installed in Sheffield as result of this award has led a Leverhulme visiting Professorship award that aims to gain a better theoretical understanding of organic semiconductors.
The energy filtering system is instrumental to EPSRC Fellowship grant, SEE MORE: SECONDARY ELECTRON EMISSION - MICROSCOPY FOR ORGANICS WITH RELIABLE ENGINEERING-PROPERTIES (EP/N008065/1) involving two industrial partners (Dyesol Uk and InnoviaFilms). It will also be used for the investiagtion of degradation mechanisms in printable photovoltaic devices (EP/M025020/1),
Sectors Chemicals,Electronics,Energy,Manufacturing, including Industrial Biotechology

 
Description transfer of use of energy filtered Scanning Electron Microscopy at a large scale manufacturer in different sector (not semiconductor) is currently being investigated
First Year Of Impact 2014
Sector Electronics,Energy
 
Description EPSRC Early career Fellowship
Amount £1,004,316 (GBP)
Funding ID EP/N008065/1 
Organisation Engineering and Physical Sciences Research Council (EPSRC) 
Sector Public
Country United Kingdom
Start 02/2016 
End 01/2021
 
Description Leverhulme Visiting Professorships
Amount £11,061 (GBP)
Funding ID VP1-2014-011 
Organisation The Leverhulme Trust 
Sector Charity/Non Profit
Country United Kingdom
Start 12/2014 
End 02/2015
 
Description Royal Society International Exchanges
Amount £11,905 (GBP)
Funding ID IE140211 
Organisation The Royal Society 
Sector Charity/Non Profit
Country United Kingdom
Start 09/2014 
End 08/2017
 
Description FEI 
Organisation FEI company
Country United States 
Sector Private 
PI Contribution We developed a method of dopant contrast in a scanning electron microscope using energy filtered secondary electrons. We delivered this technique to FEI
Collaborator Contribution FEI donated to us a scanning electron microscope for this project and also made for us an energy filtering attachment.
Impact A method for the quantitative mapping of dopants in a SEM
Start Year 2007
 
Description Thermofisher 
Organisation Thermo Fisher Scientific
Country United States 
Sector Private 
PI Contribution experimental data collection and analysis
Collaborator Contribution provided energy filtering system to Sheffield, provided training and modelling data
Impact 10.1088/1742-6596/241/1/012074; 10.1088/1742-6596/209/1/012053; 10.1017/S1431927610053754; DOI: 10.1016/j.ultramic.2010.04.008; 10.1016/j.elspec.2017.08.001
Start Year 2007