Nano-Immunology
Lead Research Organisation:
University of Oxford
Department Name: UNLISTED
Abstract
Research by my group aims to unravel nanoscopic changes at the molecular level in living cells to characterise important molecular processes on the cell membrane as well as inside the cell during immunological reactions. Because many cellular responses lead to changes so subtle at the molecular level, studying them requires us to not only observe them with a superior spatial resolution but also to reach a sensitivity that is able to monitor single molecules over time and space. We are using the newest and most powerful super-resolution far-field microscopes (such as STED, RESOLFT or PALM/STORM) to image and analyse cellular structures and protein-protein and protein-lipid interactions at a level of fine detail that until now has not been possible due to the limited spatial resolution of conventional optical far-field microscopes. By combining these super-resolution microscopy techniques with single-molecule sensitive detection methods (such as fluorescence correlation spectroscopy) and fast spatio-temporal tracking tools we are able to see complex dynamic processes otherwise invisible because of the lower power of conventional far-field microscopy. These molecular interactions play an important role in the immune response to infection and cancer and so we intend to use and further develop these advanced microscopy techniques and apply them to gather new insights in immunological research.
Technical Summary
Single-molecule super-resolution microscopy of membrane dynamics: Many cellular responses lead to subtle changes on the molecular level, demanding not only for a superior spatial resolution of the analyzing method but also for the sensitivity to monitor single molecules over time and space. The combination of super-resolution optical fluorescence STED microscopy with single-molecule sensitive fluorescence-detection tools such as Fluorescence Correlation Spectroscopy (FCS) as well as the fast spatio-temporal tracking of single labeled molecules (single-particle tracking, SPT) allows for the disclosure of complex dynamic processes otherwise impeded by the limited spatial resolution of conventional far-field microscopy. For example, STED-FCS or SPT offer us the possibility to gain novel insights into important cellular processes, such as lipid-lipid, lipid-protein, and protein-protein interactions and the formation of so-called “lipid-rafts” in the cellular plasma membrane. These molecular interactions play an important role in the cellular immune response. We will therefore apply and further develop the STED-FCS and SPT microscopy techniques to highlight important molecular processes on the plasma membrane as well as inside the cell during immunological reactions. For example, these techniques will be used to shed new light on different molecular pathways triggered at the cell surface and intracellularly during antigen presentation by dendritic cells and T cell activation.
Organisations
People |
ORCID iD |
Christian Eggeling (Principal Investigator) |
Publications
Galiani S
(2023)
Super-resolution microscopy and studies of peroxisomes.
in Biological chemistry
Gutowska-Owsiak D
(2018)
Orchestrated control of filaggrin-actin scaffolds underpins cornification.
in Cell death & disease
Gutowska-Owsiak D
(2020)
Addressing Differentiation in Live Human Keratinocytes by Assessment of Membrane Packing Order.
in Frontiers in cell and developmental biology
Hertzog J
(2018)
Infection with a Brazilian isolate of Zika virus generates RIG-I stimulatory RNA and the viral NS5 protein blocks type I IFN induction and signaling.
in European journal of immunology
Hufsky F
(2023)
The International Virus Bioinformatics Meeting 2023.
in Viruses
Insausti S
(2022)
Functional Delineation of a Protein-Membrane Interaction Hotspot Site on the HIV-1 Neutralizing Antibody 10E8.
in International journal of molecular sciences
Jenkins E
(2018)
Reconstitution of immune cell interactions in free-standing membranes.
in Journal of cell science
Koerfer A
(2023)
Influence of different surface cleaning methods on STED-FCS and scanning STED-FCS calibration measurements
in Journal of Microscopy
Kokot B
(2021)
How to control fluorescent labeling of metal oxide nanoparticles for artefact-free live cell microscopy.
in Nanotoxicology
Related Projects
Project Reference | Relationship | Related To | Start | End | Award Value |
---|---|---|---|---|---|
MC_UU_00008/1 | 01/04/2017 | 31/03/2023 | £2,738,000 | ||
MC_UU_00008/2 | Transfer | MC_UU_00008/1 | 01/04/2017 | 31/03/2023 | £1,821,000 |
MC_UU_00008/3 | Transfer | MC_UU_00008/2 | 01/04/2017 | 31/03/2023 | £2,257,000 |
MC_UU_00008/4 | Transfer | MC_UU_00008/3 | 01/04/2017 | 31/03/2023 | £1,459,000 |
MC_UU_00008/5 | Transfer | MC_UU_00008/4 | 01/04/2017 | 31/03/2023 | £1,346,000 |
MC_UU_00008/6 | Transfer | MC_UU_00008/5 | 01/04/2017 | 31/03/2023 | £1,660,000 |
MC_UU_00008/7 | Transfer | MC_UU_00008/6 | 01/04/2017 | 31/03/2023 | £401,000 |
MC_UU_00008/8 | Transfer | MC_UU_00008/7 | 01/04/2017 | 31/03/2024 | £2,876,000 |
MC_UU_00008/9 | Transfer | MC_UU_00008/8 | 01/04/2017 | 31/03/2023 | £2,568,000 |
MC_UU_00008/10 | Transfer | MC_UU_00008/9 | 01/04/2017 | 31/03/2023 | £2,060,000 |
MC_UU_00008/11 | Transfer | MC_UU_00008/10 | 01/04/2017 | 31/03/2023 | £1,477,000 |