Fouling in heat exchangers of crude distillation units

Lead Research Organisation: University of Bath
Department Name: Chemical Engineering

Abstract

Abstracts are not currently available in GtR for all funded research. This is normally because the abstract was not required at the time of proposal submission, but may be because it included sensitive information such as personal details.
 
Description The principal finding from Bath's research was that crude oil fouling could be studied (and hence modelled) using a small (1 litre) batch stirred cell as opposed to a a much larger and more complex flow loop. The new cell could be operated up to 30 bar pressure and 400 Celsius surface temperature. The batch stirred cell allowed experiments to be conducted comparatively quickly. Couple with computational fluid dynamics (CFD), all the parameters which influence fouling could be studied and the deposits characterised by Imperial College and elsewhere.
URL http://www3.imperial.ac.uk/crudeoilfouling
 
Description Esdu International Plc 
Organisation Esdu International
Country United States 
Sector Private 
Start Year 2006
 
Description Imperial College London 
Organisation Imperial College London
Country United Kingdom 
Sector Academic/University 
Start Year 2006
 
Description University of Cambridge 
Organisation University of Cambridge
Country United Kingdom 
Sector Academic/University 
Start Year 2006